Core Advantages:
●Standard Maximum
●charging output-250KW
●Liquid-Cooling Maximum
●charging output-600kW
●Dynamic Load-based power allocation
●GBT/cCs2/ccs1
Description:
The D9-600KW liquid-cooled ultra-fast charger features a split design: a power cabinet (IP65 rated, -40°C to +75°C operation) housing liquid-cooled conversion modules, and a terminal with a lightweight 600A liquid-cooled gun. It delivers 150-1000V output, enabling 300km range in 5 minutes. The system supports multi-gun dynamic power distribution and V2G integration.
Applications:
● Highway service stations: Enable rapid replenishment for long-distance EVs, reducing wait times.
● Large-scale EV charging hubs: Support high-volume, centralized, and efficient charging demands.
● Urban core commercial district parking: Facilitate fast charging needs during drivers' brief stays.
Introduction
Product Technical Specifications
Model | D6-120K2E | D6-160K2E | D6-180K2E | D6-240K2E | |
Input | Power Supply | Three-phase 3P+N+PE | |||
Rated Votage | 380VAC±15% | ||||
Rated Current | 200A | 260A | 300A | 380A | |
Frequency | 50/60HZ | ||||
Output | Votage | 200-1000VDC | |||
Current | 250A | 250A | 250A | 250A | |
Power | 120KW | 160KW | 180KW | 240KW | |
UserInterface | LED Indicator | Light Color Indicator | |||
RFID Reader | ISO/IEC 14443 | ||||
Start Mode | APP/RFID Card | ||||
Communication | Supported | RJ45/4G | |||
Protocol | OCPP 1.6 Json | ||||
Max RFOutput | <20dBm(-10dBm) | ||||
Safety | RCD | RCD Type AC(30) | |||
Ingress Protection | Ip54 | ||||
Impact Protection | Ik08 | ||||
E lectrcaProtection | Over current protection,Residual current protection,Surge protection Over/Under voltage protection,Over temperature protection | ||||
Warranty | 2 years | ||||
Environment | Installation | Floor mount | |||
WorkingTemperature | -30℃~50℃ | ||||
Working Humidity | 5%~95% | ||||
Work Altitude | <2000m | ||||
Package | Product Dimension | 915*550*1695mm(L*W"H) | |||
Packge Dimension | 1050*710*1830mm |
FAQ:
Q1: Transport damage prevention?
A1: Verify cargo space fits host (1800×800×2100mm) & terminal (500×280×1650mm). Use shock-proof packing, secure cooling modules/gun ports. Check coolant pre-long transport.
Q2: Host-terminal comms failure?
A2:Verify COM cable (RVVSP 1.5mm²) connections per Fig. 17. If unresolved, reboot the host and check logs for "CAN timeout" errors; update terminal firmware if needed
Q3: Performance in extreme cold/heat (-30°C/50°C)?
A3: Operates at -39°C to 50°C via PTC heaters (low temp) and variable-speed coolant pumps (high temp). Features IP68-sealed modules, anti-condensation coatings, and removable air filters for dust/sand protection
Q4:Payment Interface Error" Causes
A4:① Check LAN indicator status; reset router if flickering. ② Verify payment platform status; contact provider if "service unavailable". ③ Ensure SIM signal ≥3 bars; replace 4G module if weak
Q5:Over-Temperature Protection" Shutdown
A5:Inspect cooling fans; replace if faulty. If fans work, check ambient ventilation (1m clearance required) or calibrate sensors if backend shows normal temps (<65°C)